This section provides illustrations of the primary windows with explanations of the pull-down menu options on their menu bars. The discussions include:
The menu bar displays the titles of seven menus:
The File menu displays the options you can use to create new programs, view or edit previously created programs, load macros, and save programs. You must have write permission for a file to save changes directly to that file.
The following options appear on the File menu:
New | Initializes the VPE for a new program and clears the canvas. If you have opened Control Panels and Image windows from the VPE, they are closed. If a program you changed but did not save currently exists on the canvas, a dialog box appears so you can save changes. If you opened the VPE using Open Macro or Open Visual Program Editor, this option is grayed out. |
Open Program... | Opens an existing visual program. A dialog box appears for you to specify the desired program name. If a program you changed but did not save currently exists on the canvas, a dialog box appears asking if you want to save changes. If you opened the VPE using Open Macro, this option is grayed out. See "File Selection Dialog Boxes" for more information. |
Save Program | Saves the current visual program, and associated Control Panels. This option saves the following files: filename.net (for network; that is, a Data Explorer visual program); filename.cfg (for configuration). |
Save Program As... | Saves the current visual program and all associated Control Panels under a name you type into the dialog box. This option saves the following files: filename.net (for network; that is, a Data Explorer visual program), filename.cfg (for configuration). |
Program Settings | Brings up a cascade menu with two choices:
|
Load Macro... | Loads a macro and makes it available in a tools palette. A file selection dialog box appears for you to specify the desired macro file name. See also "Loading Macros" |
Load Module Definition(s)... | Loads a module definition and makes it available in a tool palette. A file selection dialog box appears for you to specify the desired module file name. The executable you are using must either include this module, or this module definition must refer to an outboard or run-time loadable module. See 9.2 , "Loading and Using Outboard and Runtime-Loadable Modules". |
Print Program... | Prints or saves to a file a representation of a visual program. If the Label Set Input toggle button is activated, then any parameter value(s) set in the configuration module's Configuration dialog box will also be printed next to the corresponding tab(s), if scale allows.
|
Quit or Close | Closes all windows created from the current VPE window. If you have made changes since the last save, a dialog box appears so you can save changes. If you opened the VPE from the Image window or with the Open Macro option, Close appears as an option instead of Quit. Quit is grayed out if the Execute menu title is highlighted. You must select the End Execution option in the Execute pull-down menu; or if the Sequencer is running, you must stop it or pause before quitting. |
The Edit menu lists options for manipulating tools on the canvas.
Configuration... | Displays a Configuration dialog box for setting and changing the values of the selected tool. See "Entering Values in a Configuration Dialog Box". | ||||||||||||||||||
Find tool... | Opens a dialog box that lists the tools in the visual network displayed on the canvas. Double-click on the tool name (or type the name in the Selection field) to highlight the corresponding icon in the canvas. If the icon falls outside the canvas, the canvas will automatically scroll to display the part of the network in which it lies. | ||||||||||||||||||
Input/Output Tabs | Brings up a cascade menu with the following options:
| ||||||||||||||||||
Assign Get/Set Scope | Brings up a cascade menu with the following options:
| ||||||||||||||||||
Select/Deselect Tools | Brings up a cascade menu with the following options:
| ||||||||||||||||||
Output Cacheability | Brings up a cascade menu with the following options:
| ||||||||||||||||||
Delete | Deletes the selected tools and connections to other tools. | ||||||||||||||||||
Cut | Deletes the selected tools but places them into a buffer so they can be pasted. | ||||||||||||||||||
Copy | Copies the selected tools and places them into a buffer so they can be pasted. | ||||||||||||||||||
Paste | Pastes the tools from the buffer into a selected location | ||||||||||||||||||
Add Annotation | Adds annotation text to the canvas (see "Adding Annotation to a Visual Program"). | ||||||||||||||||||
Insert Visual Program | Brings up a file selection dialog box for selecting a visual program. The selected program will be inserted to the right of all the tools in the current program. | ||||||||||||||||||
Create Macro | Creates a macro from the currently selected tools. See "Creating Macros" for more information. | ||||||||||||||||||
Page | Brings up a cascade menu with the following options:
| ||||||||||||||||||
Macro Name ... | Displays a Configuration dialog box for naming a visual program as a macro. See "Creating Macros" for more information. | ||||||||||||||||||
Execution Groups... | Displays a dialog box for creating and modifying execution groups. (See 9.1 , "Using Distributed Computation".) | ||||||||||||||||||
Comment ... | Displays a dialog box for documenting the function of a visual program or macro. (See "Adding Comments to a Visual Program".) |
The Execute menu lists the following options:
Execute Once | Causes the visual program to execute only once, using current values and configuration settings. Subsequent interactor value changes do not cause program reevaluation until this command is reexecuted. This option is grayed out if the Sequencer is running. |
Execute on Change | Causes the visual program to execute each time a value or configuration setting is changed. If you are changing values faster than Data Explorer can generate images, the program executes as fast as possible, always using the current settings at the time an execution cycle begins. This option is grayed out if the Sequencer is running. |
End Execution | Causes the visual program to stop executing. |
Sequencer | Causes the Sequencer to display. This option is grayed out if there is no Sequencer in the visual program. While the Sequencer is running, you can change interactors, and those changes are reflected in subsequent frames. You can pause the Sequencer on a particular frame and explore that frame using the Execute Once and Execute on Change options. "Using the Sequencer" discusses the Sequencer in detail. |
While the visual program is executing, the Execute label in the menu bar is highlighted and remains so until execution is completed. If Execute on Change is selected, the Execute label in the menu bar is highlighted with one color during execution, and another color the rest of the time.
For more information, see 5.4 , "Executing a Visual Program".
The Windows menu allows a user to open and create control panels, open previously defined macros included in the visual program, open the Image window, and open the Colormap Editor.
These options appear on the Windows menu:
New Control Panel | Opens a new Control Panel. If you have selected one or more interactor stand-ins on the VPE canvas, the new Control Panel contains those interactors. If you have not selected anything on the canvas, the panel is empty. |
Open Selected Control Panel(s) | Opens all Control Panels containing selected (highlighted) interactor stand-ins. Control Panels that are already open are unaffected.
|
Open All Control Panels | Opens all the Control Panels for the current visual program. |
Open Control Panel by Name | Opens a cascade menu with the names of the existing control panels. Using this, you can open a particular control panel. |
Open Selected Macro(s) | Opens a VPE window containing the expanded representation of the selected macro icon. From this newly opened window, you can open the macros contained in the currently opened macro. You can repeat this operation until only modules are contained in the window. See "Using Macros in a Visual Program" for more information. This options is grayed out if no macro is selected. |
Open Selected Image Window(s) | Opens an Image window for each selected Display or Image tool icon in the current visual program. This option is grayed out if no Display or Image icons are selected. |
Open Selected Colormap Editor(s) | Opens a window where you can map colors and opacities to data values, the results of which are displayed in the visual image. This option is grayed out if a Colormap icon is not selected. Features of the Colormap Editor allow you to:
|
Open Message Window | Opens a window where you can access error and warning messages and working information about your execution. See 8.2 , "Using the Message Window". |
The Connection menu lists the following options:
Start Server | Connects the user workstation to the server. For more information, see 9.3 , "Connecting to the Server". |
Disconnect from Server | Disconnects the user workstation from the server. |
Reset Server | Flushes the cache, forcing the visual program to reaccess the data on the server the next time it executes. |
Execution Group Assignment... | Displays a dialog box that allows you to assign execution groups to specific machine host names. |
The Options menu allows you to customize tools and window features.
The Options menu lists the following options:
Tool Palettes | Toggles between displaying the tool palettes and not displaying them. You can also use the Ctrl+T accelerator key. |
Control Panel Access... | Allows you to specify which controls panels and control panel groups are accessible from the VPE. (See "Control Panel Access, Groups, and Hierarchies".) |
Control Panel Groups... | Displays a dialog box that allows you to create, modify and delete control panel groups. (See "Control Panel Access, Groups, and Hierarchies".) |
Grid ... | Allows you to select the grid type you want to use on the canvas. A dialog box displays the choices. See "Customizing the VPE Window" for more information about the Grid... option. |
The options in this menu are discussed in 5.3 , "Using Online Help".
The Control Panel menu bar (Figure 60) displays the names of six menus you can use within the Control Panel window:
The File menu lists the following options:
Close | Closes the current Control Panel. |
Close All Control Panels | Closes all control panels. |
Set Style... | Allows you to change the type of selected interactors on the layout area. See "Changing the Interactor Style". |
Set Dimensionality... | Allows you to set the dimensionality of the selected interactors in the layout area. See "Changing the Interactor Dimensionality". |
Set Layout... | Allows you to set the layout of the selected interactors in the layout area. You can specify horizontal or vertical. See "Changing the Interactor Layout". |
Set Attributes... | for integer, scalar, and vector values, allows you to specify:
You can also open the Set Attributes window by double clicking on the border area of the interactor inside the Control Panel. See "Setting Interactor Attributes" for detailed information. |
Set Label | Allows you to change the title of the interactor. See "Changing the Label on the Interactor". |
Delete | Deletes selected interactors. |
Add Element | Brings up a cascade menu with the choices Label and Separator. These can then be added to the control panel. See "Control Panels as Dialog Boxes". |
Add Selected Interactor(s) | Adds an interactor to the Control Panel for each stand-in that is selected in the VPE window. See "Adding Interactors to an Existing Control Panel". |
Show Selected Interactor(s) | Shows the relation between a selected interactor stand-in in the VPE and the interactors in the Control Panels. See "Locating Interactor Stand-ins". |
Show Selected Tool | Shows the relation between a selected interactor stand-in in a control panel and interactor stand-ins in the VPE. |
Comment... | Opens a dialog box with a text field. You can use this text field to document the use of the Control Panel. See "Adding Comments to a Control Panel". |
This execute menu is identical to that of the Visual Program Editor window. See "VPE Execute Menu" for descriptions of the Execute options. See also 5.4 , "Executing a Visual Program".
The Panels menu allows you to open one or all existing control panels.
The Panels menu has the following options:
Open All Control Panels | Opens all existing control panels. |
Open Control Panel by Name | Opens a cascade menu, from which you can select the name of the control panel to open. |
The Options menu allows you to customize the Control Panel.
The Options menu contains the following options:
Change Control Panel Name... | Displays a dialog box where you can enter a new name for the current Control Panel. |
Control Panel Access... | Allows you to specify which control panels and control panel groups are accessible from the Control Panel's Open All Control Panels option under the Windows menu. See "Restricting Control Panel Access". |
Grid... | Allows you to select the grid type you want to use on the layout area. A dialog box displays the choices. See "Customizing the VPE Window" for more information about the Grid... option. See "Changing the Alignment of Interactors in the Control Panel". |
Dialog Style | Changes a control panel to "dialog style" (see "Control Panels as Dialog Boxes"). |
Startup Control Panel | Allows you to specify whether the Control Panel is opened automatically when Data Explorer is started with the Image window or menu bar as the anchor window. See "Specifying a Startup Control Panel". |
The options in this menu are discussed in 5.3 , "Using Online Help".
The Image window menu bar displays the names of six menus:
The File menu lists the following options:
Open ... | Displays a dialog box for specifying a file path name to load a visual program or, if the path name ends in a directory, to show a list of visual programs in that directory. To select a program, click on the name. See "File Selection Dialog Boxes" for more information. |
Save Program | Saves the current visual program and associated Control Panels. This option saves the following files: filename.net (for network; that is, a Data Explorer visual program) and filename.cfg (for configuration). This option is grayed out unless Data Explorer was started in -image mode. |
Save Program As... | Saves the current visual program and all associated Control Panels under a name you type in the dialog box. This option saves the following files: filename.net (for network; that is, a Data Explorer visual program) and filename.cfg (for configuration). This option is grayed out unless Data Explorer was started in -image mode. |
Program Settings | Brings up a cascade menu with two choices:
|
Load Macro... | Loads a macro for use, making it available in the tool palette. A file selection dialog box appears for you to specify the desired macro file name. See "Loading Macros". |
Load Module Definition(s)... | Loads a module definition for use, making it available in the tool palette. A file selection dialog box appears for you to specify the desired module file name. The executable you are using must also include this module. See 9.2 , "Loading and Using Outboard and Runtime-Loadable Modules". |
Save Image... | Displays a dialog box that allows you to save the image and specify the format, layout, resolution, and page size of the image. See "Saving an Image". |
Print Image... | Displays a dialog box that allows you to specify the format, layout, resolution, and page size of the print. See "Printing an Image". |
Close or Quit | Closes the Image window. If you opened the Image window from the VPE, Close appears is the option. If you started Data Explorer with the Image window as the anchor, Quit is the option. Quit is grayed out if the Execute menu title is highlighted. You must select the End Execution option in the Execute pull-down menu; or if the Sequencer is running, you must stop it or pause before quitting. |
This execute menu is identical to that of the Visual Program Editor window. See "VPE Execute Menu" for descriptions of the Execute options. See also 5.4 , "Executing a Visual Program".
The Windows menu allows you to open a VPE window containing the program layout or the Control Panels associated with the visual program. All windows created from this Image window become its children. Quitting the Image window causes all of its child windows to close. Before the window closes, a dialog box appears to request confirmation.
The Windows menu offers the following options:
Open Visual Program Editor | Opens a VPE window containing the current visual program. This option is disabled if you have not loaded a visual program or if the VPE is the anchor window. |
Open All Control Panels | Opens all the Control Panels and macro Control Panels for the current visual program unless the macro Control Panels are already contained in another Control Panel. This option is disabled if you have not loaded a visual program. |
Open Control Panel by Name | Opens a cascade menu, from which you can select the name of the control panel to open. |
Open All Colormap Editors | Opens all the Colormap Editors for the current visual program. |
Open Message Window | Opens the Message Window that displays error and warning information about your execution. |
The Connection menu allows you to monitor and control communication functions between the workstation and the server.
The Connection menu lists the following options:
Start Server... | Connects the user workstation to the server. For more information, see 9.3 , "Connecting to the Server". |
Disconnect from Server | Disconnects the user workstation from the server. |
Reset Server | Flushes the cache, forcing the visual program to reaccess the data on the server the next time it executes. |
Execution Group Assignment... | Displays a dialog box that allows you to assign execution groups to specific machine host names. |
The Options menu provides the following options, which are available only when the Image tool is used in a visual program:
View Control ... | Opens a dialog box with various view control options. For more information on this menu option, see "Controlling the Image: View Control...". |
Undo | Returns to the view of the image that was displayed before the most recent action (effectively undoing the action). See "Restoring Images". |
Redo | Restores the view of the image that was displayed before the last Undo action. See "Restoring Images". |
Reset | Resets the camera to its initial position and direction. See "Restoring Images". |
AutoAxes... | Places axes around the image the next time you execute the visual program. See "AutoAxes...". |
Set Background Color... | Sets the background color of the image. See "Set Background Color...". |
Display Rotation Globe | Enables and disables the wire-framed globe display in many of the view control options. While the toggle button is pressed in, the globe display is enabled. See "Rotating the Object". |
Rendering Options... | Displays a dialog box, allowing you to choose hardware or software rendering options. See "Rendering Options...". |
Image Depth | Specifies the number of bits (8, 12 or 24) per color. See "Image Depth". |
Throttle... | Specifies the minimum number of seconds to display each frame. See "Changing the Rate of Frame Display: Throttle...". |
Change Image Name... | Opens a dialog box in that you can specify a new title for the Image window. See "Changing the Title of an Image Window". |
Control Panel Access... | Allows you to specify which control panels and control panel groups are accessible from the Image Window's Open All Control Panels option under the Windows menu. See "Control Panel Access...". |
The options in this menu are discussed in 5.3 , "Using Online Help".
The Colormap menu bar displays the name of five menus you can use:
The Colormap File menu provides the following options:
New | Replaces Colormap Editor values with default values. |
Open... | Opens an existing Colormap as specified in the dialog box that appears. If a current Colormap is on display and changes have been made, a dialog box appears for applying wanted changes. |
Save As... | Saves the current Colormap configuration as the name typed into the dialog box that appears. |
Close | Closes the Colormap window. |
The Colormap Edit menu displays the options used to edit the current color map.
The following options appear on the Edit menu:
Undo | Returns an operation to its previous value. Undo retains a stack of 10 operations. | ||||||||||||
Copy | Copies selected control points to a buffer so that they can be pasted to another field. See "Copying and Pasting Control Points". | ||||||||||||
Paste | Pastes selected control points to a different field. See "Copying and Pasting Control Points". | ||||||||||||
Use Application Default | If the Colormap Editor is data-driven, it is still possible to override its data-driven values by explicitly setting them in the Colormap Editor. The Use Application Default option restores the data-driven values. It generates a cascade menu with four suboptions:
| ||||||||||||
Add Control Points... | Brings up a dialog box in which you can enter the exact numerical location for control points to be added as the data value and as the value for either the Hue, Saturation, Value, or Opacity area of the color map. See "Adding Control Points". | ||||||||||||
Constrain Horizontal | Constrains the horizontal movement of all control points in all areas of the Colormap. See "Moving Control Points". | ||||||||||||
Constrain Vertical | Constrains the vertical movement of all control points in all areas of the color map. | ||||||||||||
Generate Waveforms | Displays a dialog box that allows you to select from a menu of waveforms. The waveforms can be applied to the full range of hue, saturation, value or opacity or to a selected range. See "Creating Waveforms". | ||||||||||||
Delete Selected Control Points | Deletes selected control points in the selected area of the Colormap. | ||||||||||||
Select All Control Points | Selects all the control points in the selected area of the Colormap. |
This execute menu is identical to that of the Visual Program Editor window. See "VPE Execute Menu" for descriptions of the Execute options. See also 5.4 , "Executing a Visual Program".
The Colormap Options menu displays the options used to edit the current color map.
The Colormap Options menu lists the following options:
Set Background Style to Checkerboard (or Stripes) | Changes the background bar from two vertical stripes to a checkerboard. Note: The opacity must be less than 1 to make this pattern visible. |
Axis Display | Allows you to choose between Ticks, Histogram, and Log(Histogram). See "Axis Display". |
Number of histogram bins... | Allows you to select the number of histogram bins. See "Axis Display". |
Display Control Point Data Value | Allows you to specify which control point values will be displayed. See "Display Control Point Values" |
Change Colormap Name | Sets the name of the Colormap Editor. See "Changing the name of the Colormap Editor". |
The options in this menu are discussed in 5.3 , "Using Online Help".
A menu bar is displayed as the anchor window when the user specifies the -menubar option on the command line to Data Explorer. The menu bar displays the titles of five menus:
The File menu lists the following options:
Open ... | Displays a dialog box for specifying a file path name to load a visual program or, if the path name ends in a directory, to show a list of visual programs in that directory. To select a program, click on the name. See "File Selection Dialog Boxes" for more information. |
Program Settings | Brings up a cascade menu with two choices:
|
Load Macro... | Loads a macro for use, making it available in the tool palette. A file selection dialog box appears for you to specify the desired macro file name. See "Loading Macros". |
Load Module Definition(s)... | Loads a module definition for use, making it available in the tool palette. A file selection dialog box appears for you to specify the desired module file name. The executable you are using must also include this module. See 9.2 , "Loading and Using Outboard and Runtime-Loadable Modules". |
Quit | Closes the Menu Bar window |
This execute menu is identical to that of the Visual Program Editor window. See "VPE Execute Menu" for descriptions of the Execute options. See also 5.4 , "Executing a Visual Program".
The Connection menu allows you to monitor and control communication functions between the workstation and the server.
The Connection menu lists the following options:
Start Server... | Connects the user workstation to the server. For more information, see 9.3 , "Connecting to the Server". |
Disconnect from Server | Disconnects the user workstation from the server. |
Reset Server | Flushes the cache, forcing the visual program to reaccess the data on the server the next time it executes. |
Execution Group Assignment... | Displays a dialog box that allows you to assign execution groups to specific machine host names. |
The Windows menu allows you to open a VPE window containing the program layout or the Control Panels associated with the visual program. All windows created from this Image window become its children. Quitting the Image window causes all of its child windows to close. Before the window closes, a dialog box appears to request confirmation.
The Windows menu offers the following options:
Open Visual Program Editor | Opens a VPE window containing the current visual program. This option is disabled if you have not loaded a visual program or if the VPE is the anchor window. |
Open All Control Panels | Opens all the Control Panels and macro Control Panels for the current visual program unless the macro Control Panels are already contained in another Control Panel. This option is disabled if you have not loaded a visual program. |
Open Control Panel by Name | Opens a cascade menu, from which you can select the name of the control panel to open. |
Open All Colormap Editors | Opens all the Colormap Editors for the current visual program. |
Open Message Window | Opens the Message Window that displays error and warning information about your execution. |
The options in this menu are discussed in 5.3 , "Using Online Help".
The Message window menu bar displays the names of five menus:
The Message window File menu provides the following options:
Clear | Clears the Message window. |
Log... | Allows you to designate a file that will receive all subsequent messages displayed in the Message window. |
Save As... | Saves the current contents of the Message window to the file named in the dialog box that appears. |
Close | Closes the Message window. |
The Message window Edit menu displays the options used to edit the current Message window.
The following options appear on the Edit menu:
Next Error | Displays and highlights the next error in the Message window and highlights the tool that reported it. |
Previous Error | Displays and highlights the previous error in the Message window and highlights the tool that reported it. |
This execute menu is identical to that of the Visual Program Editor window.
See "VPE Execute Menu" for descriptions of the
Execute options.
See also 5.4 , "Executing a Visual Program".
The Message window Commands menu
displays the options for running
specific commands. The following options appear on the
Commands menu:
Debug Tracing
When enabled, displays instance numbers on each tool in a visual
program (to distinguish between multiple instances of a tool) and turns on
tracing in the message window so that as each module is run its name and
instance number is displayed.
Execute Script Command
Allows commands to be issued directly to the server (see
Executive in IBM Visualization Data
Explorer User's Reference).
Show Memory Use
Displays the current memory usage (see Usage in
IBM Visualization Data Explorer User's Reference).
Message Window Commands Menu
The Message window Options menu displays the options used to edit the current Message window.
The Message Window Options menu lists the following options: See also 8.2 , "Using the Message Window".
Information Messages | Allows you to either display or not display Information messages. |
Warning Messages | Allows you to either display or not display Warning messages. |
Error Messages | Allows you to either display or not display Error messages. |
[Data Explorer Home Page | Contact Data Explorer | Same document on Data Explorer Home Page ]